| Sign In | Join Free | My insurersguide.com | 
 | 
Brand Name : Nihon Kohden
Model Number : UT-2466
MOQ : 1pcs
Payment Terms : Full before the hsi
Delivery Time : 3-5 working days
Packaging Details : Carton
Product Name : Nihon Kohden CardiofaxS ECG-2250 ECG Machine Mainboard UT-2466 SMT-5 94V-0 Including Display Booard USB NETWORK Connector
Brand : Nihon Kohden
Part No : UT-2466
Application : Nihon Kohden CardiofaxS ECG-2250 ECG Machine
MOQ : One piece
Warranty : 90 days
Condition : Used
Packaging : Standard
Delivery Method : DHL,UPS ,Fedex
UT-2466 Nihon Kohden CardiofaxS ECG-2250 ECG Machine Mainboard SMT-5 Including Display Booard USB NETWORK Connector
Nihon Kohden CardiofaxS ECG-2250 ECG Machine Mainboard UT-2466 SMT-5 94V-0 Including Display Booard USB NETWORK Connector
The motherboard of the Nihon Kohden Cardiofax S ECG-2250 electrocardiograph is the core component that controls and coordinates the operation of the machine. It houses the microprocessor, memory, and other electronic components needed for the machine to function. The main board receives signals from electrodes placed on the patient, processes the data, and sends the results to a monitor or printer. It also interfaces with other subsystems of the machine, such as power, user interface, and communication ports. The motherboard plays a vital role in ensuring accurate and reliable recording of the patient's ECG.
| Product Name | Nihon Kohden cardiofaxS ECG-2250 ECG machine mainboard UT-2466 SMT-5 94V-0 including display booard USB NETWORK connector | 
| Brand | Nihon Kohden | 
| Part No | UT-2466 | 
| Application | Nihon Kohden cardiofaxS ECG-2250 ECG machine | 
| MOQ | One piece | 
| Warranty | 90 days | 
The sole function of an electrocardiograph, a high-precision electronic medical device, is to accurately detect, amplify, and transmit weak human electrophysiological signals to a display screen. From this, it is easy to imagine that the accuracy of the detection signal in the front stage of the electrocardiograph directly determines the accuracy of the rear stage and the overall output, and the final output result may be wrong by tens of times. or it can be more. The following five points should be considered by healthcare professionals regarding the use and maintenance of electrocardiograph electrodes and leads.
① After each use of the electrode, the conductive paste or salt water on the surface should be wiped off, so as to reduce the corrosion of the electrode as much as possible;
②If you find oxidation or rust spots on the surface of the silver-plated electrode, just use a flannel cloth to wipe it, and never use sandpaper to polish it;
③ If it is found that the electrode is deformed, the silver skin is peeled off, or part of the copper is exposed due to abrasion, then the electrode can no longer be used;
④ Do not use the new electrode replaced by the ECG machine immediately, but soak it in sodium chloride solution for several hours before use;
⑤ When pulling out the plugs of the lead wires after use, the plugs must be pulled out by hand, and the wires must not be pulled out, otherwise the wires will be easily damaged or even broken..

Thank you so much for your attention .If you're interested in UT-2466 Nihon Kohden CardiofaxS ECG-2250 ECG Machine Mainboard SMT-5 Including Display Booard USB NETWORK Connector ,feel free to contact me .Thank you .
|   | 
| UT-2466 Nihon Kohden ECG Machine Parts Mainboard SMT-5 Including Display Booard USB Network Connector Images | 
 Edan SE-1200 Express ECG/EKG Machine Display (800*600 Multicolor LCD Screen)
                                                                                    
                        
                        
                        
                                                            Edan SE-1200 Express ECG/EKG Machine Display (800*600 Multicolor LCD Screen)
                                                    
                        
                     SCHILLER AT-101 ECG Machine Top Cover White Spare Parts for ECG Machine with
                                                                                    
                        
                        
                        
                                                            SCHILLER AT-101 ECG Machine Top Cover White Spare Parts for ECG Machine with
                                                    
                        
                     Mortara ELI 250 ECG Machine FUSE Used In Good Working Black Color ECG Monitor
                                                                                    
                        
                        
                        
                                                            Mortara ELI 250 ECG Machine FUSE Used In Good Working Black Color ECG Monitor
                                                    
                        
                     Pagewriter TC10 Long 10 Lead Patient Cable AHA 3.8 M 12.5´ Long AAMI 98980318495
                                                                                    
                        
                        
                        
                                                            Pagewriter TC10 Long 10 Lead Patient Cable AHA 3.8 M 12.5´ Long AAMI 98980318495
                                                    
                        
                     Masima Patient Cable LNC MP10 2281 MP Series Patient Cables In Good Working
                                                                                        
                                                        
                        
                        
                        
                                                            Masima Patient Cable LNC MP10 2281 MP Series Patient Cables In Good Working
                                                    
                        
                     Mortara ELI 250 ECG Machine Key Membrane ECG Machine Part In Good Working
                                                                                    
                        
                        
                        
                                                            Mortara ELI 250 ECG Machine Key Membrane ECG Machine Part In Good Working
                                                    
                        
                     Nihon Kohden ECG-6951E ECG display MTG3417-A1 CMF-TG3417DFSW-W D0936 used in
                                                                                        
                                                        
                        
                        
                        
                                                            Nihon Kohden ECG-6951E ECG display MTG3417-A1 CMF-TG3417DFSW-W D0936 used in
                                                    
                        
                     ECG-3010 Biocare Digital ECG Machine Electrocardiograph 3 Channel
                                                                                    
                        
                        
                        
                                                            ECG-3010 Biocare Digital ECG Machine Electrocardiograph 3 Channel
                                                    
                        
                     Mortara ELI 250 ECG Machine Keypad Board 5525-040-02B 26025-040-51 In Good
                                                                                    
                        
                        
                        
                                                            Mortara ELI 250 ECG Machine Keypad Board 5525-040-02B 26025-040-51 In Good
                                                    
                        
                     SCHILLER AT-101 ECG Machine Printer 98.30.000.002-00 Accessories Medical Printer
                                                                                    
                        
                        
                        
                                                            SCHILLER AT-101 ECG Machine Printer 98.30.000.002-00 Accessories Medical Printer